Yodify Product Library
Add the Series II Standard Mass Flow Controller to your store or catalog  
Book Your Demo and See How
or create your store

Series II Standard Mass Flow Controller

Brand: Parker Hannifin

Parker's highly precise mass flow controllers provide you the diagnostic stability and repeatability you need for low flow gas applications. 

Controlling thermal mass flow rates from 0.6 l/m to 1,670 l/m with high precision and <0.2% repeatability.  

Rated for 8 separate gas types which are customer field adjustable. 

Our thermal mass flow controller is available in both digital and analog styles, fully compatible with RS232 and digital protocols such as Profibus.  

If you're not sure what gas you're going to use or your process changes, our MFC allows you to migrate to a new gas within your flow range without purchasing a new mass flow controller
Features
  • Fast, Repeatable and Reliable Performance 
  • Premium Accuracy with Proven Thermal Mass Flow Sensor and Laminar Flow Element 
  • Easy to integrate into your new or existing systems 
  • Asset calibration management software included 
  • Cleaned for analytical use 
  • Fails shut with Normally Closed Valve for safe operation 
  • CE, REACH and RoHS II

Specifications

Approvals & Certifications

  • IP40

Attitude Sensitivity

  • Maximum

Body Material

  • 316L Stainless Steel

Communication Interface

  • Analog or Digital: RS-232, DeviceNet, PROFIBUS-DP, Modbus-RTU

Connection Material

  • 316L Stainless Steel

Connection Size

  • 1/8" - 1/2" / 6 mm - 20 mm

Connection Type

  • Compression, Face Seal Male, None, Other

Control Stability

  • < ± 0.1 % of Full Scale (Typical for 1 L/minute N₂)

Controllable Pressure Range

  • 928 psia - 1450 psia

Electrical Connectors

  • 9-Pin D-Connector

Flow Range

  • Up to 1670 L/minute

Flow Rate Accuracy

  • Standard: ± 0.5 % of Reading Plus ± 0.1 % of Full Scale (± 1 % of Full Scale for Ranges 3 - 5 mL/minute, ± 2 % of Full Scale for Ranges < 3 mL/minute)

Internal Valve Position

  • Normally Open, Normally Closed

Leak Integrity (L/sec)

  • Tested < 2 x 10-9 Mbar L/sec He

Maximum Operating Temperature (°C)

  • 70° C

Minimum Operating Temperature (°C)

  • -10° C

Power Consumption

  • Maximum

Power Supply

  • +15-24 Vdc

Pressure Coefficient (ATM)

  • 0.1 ATM Typical N₂, 0.01 % / ATM Typical H₂

Repeatability

  • < 0.2 % Reading

Seal Material

  • EPDM, Kalrez, Viton (Standard)

Settling Time

  • Standard: 2 - 4 seconds

Surface Finish (Ra)

  • 0.8 µm Typical

Temperature Coefficient (°C)

  • Zero: < 0.05 % of Full Scale/°C, Span: < 0.05 % of Reading/°C

Turndown Accuracy

  • 1: 50 (In Digital Mode up to 1:187.5)

Warm-Up Time

  • 30 Min for Optimum Accuracy 2 Min for Accuracy ± 2 % of Full Scale

Wetted Materials

  • 316L Stainless Steel

  • Gas Control for Laboratory and Process Equipment 
  • Burner Ratio Control for Ceramics and Metals 
  • Process and Environmental Analyzers 
  • Emissions Monitors and Calibrators
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more