Yodify Product Library
Add the ACFoam®-II - GRF Roof Insulation to your store or catalog  
Book Your Demo and See How
or create your store

ACFoam®-II - GRF Roof Insulation

Brand: Atlas Roofing Corporation

Closed-cell polyisocyanurate (polyiso) foam core integrally bonded to non-asphaltic, fiber-reinforced organic felt facers.

ACFoam-II is offered in a variety of thicknesses, providing long-term thermal resistance (LTTR) values from 5.7 to 26.8. Available in 4ft x 8ft (1220mm x 2440mm) and 4ft x 4ft (1220mm x 1220mm) panels.

Manufactured in accordance with ASTM C1289, Type II, Class 1, Grade 2 (20 psi) or Grade 3 (25 psi) and CAN/ULC-S704 Type 2, Class 3 or Type 3, Class 3.

Also available in non-hal.

Manufactured and tested for use in new and re-roofing applications. ACFoam-II is used in built-up (BUR), modified bitumen, metal, ballasted single-ply, mechanically attached single-ply and adhered single-ply roofing systems.

These roofing systems depend on proper installation for successful performance. Refer to FM Approvals® RoofNav and UL Online Certifications Directory for additional application details.

Specifications

Compliances

  • ASTM C1289, Type II, Class 1, Grade 2 (20 psi) or Grade 3 (25 psi)
  • CAN/ULC-S704, Type 2, Class 3 or Type 3, Class 3
  • CCMC No. 12464-L
  • UL Certified for Canada - Insulated Roof Deck Assemblies Construction No. C38 and 52. Meet CAN/ULC-S126, CAN/ULC-S101 and CAN/ULC-S107
  • UL Standard 1256 Classification Construction No. 120, 123 & 292
  • UL Standard 790 (ASTM E108) Roofing Systems Classification
  • UL Standard 263 (ASTM E119) Fire Resistance Classification
  • UL Standard 1897 Uplift Resistance
  • FM Standard 4450/4470 Approved Refer to FM Approvals RoofNav for Specific System Details
  • IBC Chapter 26 & NBC Sections on Foam Insulation
  • California State Insulation Quality Standards and Title 25 Foam Flammability Criteria (License #T 1231)
  • Miami-Dade County Approved
  • State of Florida Product Approval (FL17989)

Dimensional Stability

  • ASTM D2126
  • < 2 %

Compressive Strength

  • ASTM D1621
  • 20 psi (140 kPa) or 25 psi (172 kPa)

Water Absorption

  • ASTM C209 & D2842
  • < 1.5 %, < 3.5 %

Water Vapor Transmission

  • ASTM E96
  • < 1.5 perm (85.5ng/(Pa•s•m²))

Product Density

  • ASTM D1622
  • Nominal 2.0 pcf (32.04 kg/m³)

Flame Spread

  • ASTM E84 (10 min.)
  • 40-60

Smoke Development

  • ASTM E84 (10 min.)
  • 50-170

Tensile Strength

  • ASTM D1623
  • > 730 psf (35 kPa)

Service Temperature

  • -100° to +250° F