Yodify Product Library
Add the PMA 10 Portable Oxygen Analyser to your store or catalog  
Book Your Demo and See How
or create your store

PMA 10 Portable Oxygen Analyser

Brand: M&C TechGroup Germany GmbH

The portable M&C oxygen analyzer PMA 10 is an non-thermostated instrument which has been designed for continuous and discontinuous measurement of oxygen concentrations in dry and particle-free sample gases. 

The PMA 10 is a reliable and easy-to-operate instrument and immediately operable.
Features
  • Portable and rugged instrument, lightweight
  • Analog and digital linear indication
  • Physical measuring principle
  • Small stagnant volume, fast response time
  • High accuracy and reliability
  • Approved according to DIN EN 14181 response to 13th and 17th BImSchV and TUV certificate TA-Luft as option

Specifications

Accuracy

  • Accuracy after Calibration: Analog = ± 1 % of Span / Digital = ± 0.1 Vol % O₂ Error of Precision

Ambient Temperature Range

  • -10° to 55° C (14° to 131° F)

Approvals & Certifications

  • DIN EN 14181 Resp. to 13th & 17th BImSchV
  • Electrical Standard: EN 61010
  • TÜV Certificate TA-Luft as Option

Battery Life

  • Battery Capacity 10 Hours, Recharge Time of Battery 14 Hours with Instrument Off

Electrical Connectors

  • Mains Supply: 3-Pole Chassis Plug with 2 m of Cable
  • Signal: 3-Pole Plug

Enclosure, Body Material

  • Plastic

Environmental Protection

  • IP41 EN 60529

Flow Rate

  • Flow Rate of Sample Gas: Max.
  • Influence of Sample Gas Flow Variation in Gas Flow between 0 to 60 NL/hr Air Will Cause A Difference of 0.1 Vol % O₂

Humidity

  • 0 to 90 % RH

Indication

  • Analog / Digital Meter: Analog Meter Selectable for each Range with a Scale of 0-30 & 0-100 % Digital Meter, 3-1/2-digit 9 mm (0.35") High LCD for 0-100 % O₂ Reading, Selectivity 0.1 Vol % O₂

Materials of Construction

  • Materials in Contact with Sample Gas: 316 Stainless Steel
  • Materials in Contact with Sample Gas: Epoxy Resin
  • Materials in Contact with Sample Gas: FPM
  • Materials in Contact with Sample Gas: Glass
  • Materials in Contact with Sample Gas: Platinum
  • Materials in Contact with Sample Gas: Polypropylene

Measuring Range

  • 0 to 100 % by Volume, Linear

Output

  • Output Signal: 0-1 V
  • Output Signal: 0-1 Vdc, Non-Isolated, Load > 100 kΩ, for each Selected Range
  • Output Signal: 0-20 mA for Each Selected Range, Non-Isolated, Max.
  • Output Signal: 4-20 mA for Each Selected Range, Non-Isolated, Max.

Power Supply

  • 115 Vac ± 10 %, 40 to 60 Hz, 8 VA
  • Internal Power Unit: 230 Vac Standard

Reproducibility

  • Analog = < 1 % of Span / Digital = ± 0.1 Vol % O₂ Error

Response Time

  • Response Time for 90 % of FSD: < 3 seconds at NL/hr Air

Sensitivity

  • ± 0.1 Vol % O₂/°C

Storage Temperature

  • Approximately -20° to 60° C (-4° to 140° F)

Supply Pressure

  • Sample Gas Inlet Pressure - psi: 0.145 to 14.5 (kPa: 1 to 100, bar: 0.01 to 1)

Temperature Range

  • Temperature of Sample Gas: -10° to 40° C (14° to 104° F), Dry Gas
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more