Micropilot FMR60B 80 GHz Radar Sensor
Brand: Endress+Hauser AGMicropilot FMR60B is part of the new generation of 80 GHz radar sensors. It is used for continuous non-contact level measurement in simple liquid applications with small process connections.
Wizards guide users through commissioning, proof tests and verification of the devices and thus guarantee a simple operation. Heartbeat Technology offers verification and monitoring functions to identify anomalies for more safety and increased productivity.
Micropilot FMR60B is suitable for free-space applications up to 50 m and offers high beam focusing for vessels with many internal fittings.
- Process connections: Threads and flanges
- Temperature: –40° to +200° C (-40° to 392° F)
- Pressure: –1 bis +20 bar (-14.5 to +290 psi)
- Maximum measuring range: 50 m (164 ft)
- Accuracy: ±1 mm (0.04 in)
- W-band: 80 GHz
- International explosion protection certificates, overfill prevention WHG, SIL, marine approval, 5- or 10-point factory calibration certificate
- Easy handling through intuitive operation and wizards, for commissioning and verification
- Easier troubleshooting through recommended actions shown on the display
- Reduction of systematic errors through guided SIL-locking, verification and proof testing
- Safety by design: Device development according to IEC 61508
- Increased productivity thanks to process monitoring, verification and diagnostics in the running process with Heartbeat Technology
Specifications
Brand
Characteristic / Application
- For simple continuous non-contact level measurements in liquids, pastes, and slurries
- Not influenced by changing media, temperature differences, gas phases or steam
- For vessels with many internals
Specialities
- Heartbeat Technology
- SIL 2 according to IEC 61508
- Bluetooth® commissioning
- Operation and maintenance with SmartBlue App
- HistoROM
- RFID TAG for easy identification
Supply / Communication
- 2-wire (HART/ PROFIBUS PA)
- PROFINET with Ethernet-APL
- Bluetooth® wireless technology
Frequency
- W-Band (~80 GHz)
Accuracy
- ± 1 mm (0.04 in)
Ambient Temperature
- -40° to +85° C (-40° to +185° F)
Process Temperature
- -40° to +200° C (-406 to +392° F)
Process Pressure / Max. Overpressure Limit
- Vacuum to 20 bar (290 psi)
Main Wetted Parts
- PVDF, PTFE or PEEK
Process Connection
- Thread: G 3/4" and 1-1/2", MNPT 3/4" and 1-1/2"
- Flange: UNI DN80...DN150
- Mounting bracket
Max. Measurement Distance
- 50 m (164 ft)
Communication
- HART/ PROFIBUS PA PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional)
Certificates / Approvals
- IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex, INMETRO Ex, NEPSI Ex, UK Ex
Safety Approvals
- Overfill protection WHG; SIL 2
Design Approvals
- Acceptance test certificate 3.1, EN10204
- Declaration of Conformity ASME B31.3
- AD2000
- CRN approval
- PMI test
Hygienic Approvals
- EU Food Contact Material (EC) 1935/2004
- US Food Contact Material FDA CFR 21
Marine Approval
- ABS, LR, BV, RINA, DNV
Options
- Display, Customized settings, App 'SmartBlue' for commissioning and operation via Bluetooth Gas-tight implementation
- Overvoltage protection
- PWIS free
Application Limits
- Process temp. 200° C (392° F) -> FMR62B Very aggressive media -> FMR62B Turbulences, stilling well and bypass -> FMR62B Strong foam and interfaces --> FMP5x
- For Simple Continuous Non-contact Level Measurements in Liquids, Pastes, and Slurries
- For Vessels With Many Internals
Documentation
Data Sheets
Installation Instructions
- Cover, cover seal, cover securing screw Installation Instructions pdf 612 KB
- Dummy plug M20×1.5 G½, NPT ½, NPT ¾ Installation Instructions pdf 538 KB
- EA Cable gland M20x1.5 Installation Instructions pdf 1.2 MB
- Ground terminal Installation Instructions pdf 466 KB
- HAN7D plug, 90 deg, housing side HAN7D socket, cable side Installation Instructions pdf 496 KB
- HistoROM Installation Instructions pdf 1.1 MB
- Replacement of the sensor electronics Installation Instructions pdf 1.6 MB
- Replacement of transmitter VU140 Installation Instructions pdf 727 KB
Operating Instructions
- BA Micropilot FMR60B PROFIBUS PA Operating Instructions pdf 2.4 MB
- BA Micropilot FMR60B PROFINET over Ethernet-APL Operating Instructions pdf 3.3 MB
- Housing filters Operating Instructions pdf 436 KB
- Housing Operating Instructions pdf 1.6 MB
- M12 plug (housing side) Operating Instructions pdf 1.5 MB
- Micropilot FMR60B Free-space radar HART Operating Instructions pdf 2.4 MB
- Replacement of main electronics pdf 1.0 MB
- Replacement of the connecting cables Operating Instructions pdf 1.2 MB
- Segment display VU100/VU101 Graphical display VU112/ VU113 Operating Instructions pdf 596 KB
- Sensor Operating Instructions pdf 1.7 MB
- Terminal module Operating Instructions pdf 572 KB