Yodify Product Library
Add the Testo 327-1 - Flue Gas Analyser (Standard Kit) to your store or catalog
Book Your Demo and See How
or create your store
Testo 327-1 - Flue Gas Analyser (Standard Kit)
Brand: TestoThe Testo 327-1 Flue Gas Analyser offers a robust and simple entry into flue gas analysis for domestic boilers.
It measures O₂ & CO, and will calculate ratio, CO₂, etc.
The 4-line LED display can be configured to the users requirements, and its back-lighting function guarantees an easy-to-read display even if lighting conditions are unfavourable.
The analyser stands out on account of its easy menu navigation and ergonomic housing as well as its durability.
Standard kit features include:
- 4,000ppm CO sensor with automatic pump shut off to help prevent saturation.
- 7 user selectable fuels
- Rechargeable Li-ion battery
- Tightness and let-by pressure test routines included in menu (requires pressure connection adaptor)
- Flow and return temperature measurement (using additional accessory probes)
- Soft carry case with shoulder strap
Specifications
Brand
Delivery Scope
- Testo 327 Flue Gas Analyser, Rechargeable Battery and Calibration Protocol, Flue Gas Probe (180 mm x 6 mm Diameter), Soft Carry Case with Shoulder Strap, AC Power Supply
Weight
- (with probe) Approx. 700 g
Dimensions
- 201 x 83 x 44 m
Operating Temperature
- -5° to +45° C
Display Type
- LCD (Liquid Crystal Display)
Display Function
- Backlit 2-line display
Power Supply
- Battery: 1500 mAh, mains unit 5 V/1 A
Storage Temperature
- -20° to +50° C
Temperature - TC Type K (NiCr-Ni)
- Measuring Range: -40.0° to +600.0° C
- Accuracy: ± 0.50° C (0° to 99.9° C) | ± 0.50 % of mv (100° to 600° C)
- Resolution: 0.1° C
- Reaction Time: < 50 s
- Temperature (Ambient Temperature)
Flue Gas O₂
- Measuring Range: 0 to 21 Vol. %
- Accuracy: ± 0.2 Vol. %
- Resolution: 0.1 Vol. %
- Reaction Time t₉₀: 30 s
Differential Pressure Flue Gas Draught - Piezoresistive
- Measuring Range: -40.0 to +40.0 hPa | ± 0.03 hPa (-3.00 to +3.00 hPa)
- Accuracy: ± 0.02 hPa (-0.50 to +0.60 hPa) | ± 0.03 hPa (+0.61 to +3.00 hPa) | ± 1.50 hPa (3.01 to +40.0 hPa)
- Resolution: 0.01 hPa
Flue Gas Degree of Effectivity, Eta (Calculated)
- Measuring Range: 0 to 120 %
- Resolution: 0.1 %
Flue Gas Loss (Calculated)
- Measuring Range: 0 to 99.0 %
- Resolution: 0.1 %
Flue Gas CO₂ Calculation (Calculated from O₂)
- Measuring Range: 0 to CO₂ maximum (Display range)
- Accuracy: ± 0.2 Vol. %
- Resolution: 0.1 Vol. %
- Reaction Time t₉₀: < 40 s
Flue Gas CO (Without H₂-Compensation)
- Measuring Range: 0 to 4000 ppm
- Accuracy: ± 20 ppm (0 to 400 ppm) | ± 5 % of mv (401 to 2000 ppm) | ± 10 % of mv (2001 to 4000 ppm
- Resolution: 1 ppm
- Reaction Time t₉₀: 60 s