DIL-1/ (H) Gas Dilution Unit

Brand: M&C TechGroup Germany GmbH

The M&C dilution units DIL are mounted on a plate for wall mounting. The version DIL-1 is not heated and works at ambient temperature. 

The version DIL-1/H is electrically heated up to 180°C (356°F). It is additionally equipped with a lagged cover (version for 320°C (608°F) on request). 

A capillary thermostat controls the temperature, adjustable from 0° to 180°C (32° to 356°F). A high temperature limiter and a low temperature alarm is included.
Features
  • Operation at ambient temperature
  • Optionally heated to 180°C (356°F) or 320°C (608°F)
  • Integrated dilution preheater
  • No dew point problems
  • Dilution factor from 10:1 to 500:1
  • With test gas connection
  • Independent of the ambient temperature
  • Easy maintenance and operation

1 - 8 of 8 Part Numbers
20 S 4205
20 S 4205
  • Version - DIL-1/-A: Option 1 Pressure Controller, 2 Gauges, Mounting Set for Dilution Unit
20 S 4215
20 S 4215
  • Version - DIL-1/-A1: Option 2 Pressure Controllers, 3 Gauges, Mounting Set Include Connector Set for Dilution Unit with Bypass
20 S 4250
20 S 4250
  • Version - DIL-1/-S: Mounting Set with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves
20 S 4260
20 S 4260
  • Version - DIL-1/-S1: Mounting Set with 2 Pressure Controllers, 3 Gauges, Flowmeter, 2 Ball Valve
20 S 4900
20 S 4900
  • Version - DIL-1: Dilution Unit Non Heated
20 S 4905
20 S 4905
  • Version - DIL-1/H (A): Dilution Unit Electrically Heated to 180° C (356° F)
20 S 4925
20 S 4925
  • Version - Option I: Bypass Injector - B
20 S 4930
20 S 4930
  • Version - Option II: Additional Sample Gas Outlet Undiluted
1 - 8 of 8 Part Numbers

Specifications

Electrical Rating

  • Temperature Controller: Max.

Flow Rate

  • Bypass Injector / B: Gas Pressure-Gas Flow Rate-Sample Gas Flow Rate at Approximately psig: 29.01 (kPa: 200, bar: 2) Injector Gas Approximately 300 L/hr
  • Bypass Injector / B: Gas Pressure-Gas Flow Rate-Sample Gas Flow Rate at Approximately psig: 29.01 (kPa: 200, bar: 2) Sample Gas Approximately 150 L/hr
  • Dilution Gas Flow Rate with Injector Version I: 480 to 600 NL/hr
  • Dilution Gas Flow Rate with Injector Version II: Higher Dilution Rates 1,800 to 3,000 NL/hr

Materials of Construction

  • Materials in Contact with the Sample Gas: 316 Stainless Steel
  • Materials in Contact with the Sample Gas: 316Ti Stainless Steel
  • Materials in Contact with the Sample Gas: FPM
  • Materials in Contact with the Sample Gas: Graphite
  • Materials in Contact with the Sample Gas: Quartz Glass

Mounting

  • Rack-Mounted

Operating Pressure

  • psia: 13.05 to 29.01 (kPa: 90 to 200, bar: 0.9 to 2)

Overpressure & Static Pressure Limits

  • Fault Caused by Process Under or Overpressure: No Fault as Long as the Differential Pressure ∆P at the Dilution Unit is > psig: 7.252 (kPa: 50, bar: 0.5) & Test Gas is Given to the Probe Under Process Conditions

Power Supply

  • Power Supply: 230 V 50 Hz, 800 W

Pressure Range

  • Dilution Gas Pressure on Inlet of Pressure Controller - psig: 65.27 to 232.1 (kPa: 450 to 1,600, bar: 4.5 to 16)

Ratio

  • Dilution - 10:1 to 500:1

Temperature Range

  • Electrically Heated: 0° to 320° C (32° to 608° F)
  • Temperature Controller: Capillary Thermostat Adjustable 0° to 180° C (32° to 356° F)