DIL-1/ (H) Gas Dilution Unit
Brand: M&C TechGroup Germany GmbHThe M&C dilution units DIL are mounted on a plate for wall mounting. The version DIL-1 is not heated and works at ambient temperature.
The version DIL-1/H is electrically heated up to 180°C (356°F). It is additionally equipped with a lagged cover (version for 320°C (608°F) on request).
A capillary thermostat controls the temperature, adjustable from 0° to 180°C (32° to 356°F). A high temperature limiter and a low temperature alarm is included.
Features- Operation at ambient temperature
- Optionally heated to 180°C (356°F) or 320°C (608°F)
- Integrated dilution preheater
- No dew point problems
- Dilution factor from 10:1 to 500:1
- With test gas connection
- Independent of the ambient temperature
- Easy maintenance and operation
1 - 8 of 8 Part Numbers

20 S 4205
- Version - DIL-1/-A: Option 1 Pressure Controller, 2 Gauges, Mounting Set for Dilution Unit

20 S 4215
- Version - DIL-1/-A1: Option 2 Pressure Controllers, 3 Gauges, Mounting Set Include Connector Set for Dilution Unit with Bypass

20 S 4250
- Version - DIL-1/-S: Mounting Set with 1 Pressure Controller, 2 Gauges, Flowmeter, 2 Ball Valves

20 S 4260
- Version - DIL-1/-S1: Mounting Set with 2 Pressure Controllers, 3 Gauges, Flowmeter, 2 Ball Valve

20 S 4900
- Version - DIL-1: Dilution Unit Non Heated

20 S 4905
- Version - DIL-1/H (A): Dilution Unit Electrically Heated to 180° C (356° F)

20 S 4925
- Version - Option I: Bypass Injector - B

20 S 4930
- Version - Option II: Additional Sample Gas Outlet Undiluted
1 - 8 of 8 Part Numbers
Specifications
Electrical Rating
- Temperature Controller: Max.
Flow Rate
- Bypass Injector / B: Gas Pressure-Gas Flow Rate-Sample Gas Flow Rate at Approximately psig: 29.01 (kPa: 200, bar: 2) Injector Gas Approximately 300 L/hr
- Bypass Injector / B: Gas Pressure-Gas Flow Rate-Sample Gas Flow Rate at Approximately psig: 29.01 (kPa: 200, bar: 2) Sample Gas Approximately 150 L/hr
- Dilution Gas Flow Rate with Injector Version I: 480 to 600 NL/hr
- Dilution Gas Flow Rate with Injector Version II: Higher Dilution Rates 1,800 to 3,000 NL/hr
Materials of Construction
- Materials in Contact with the Sample Gas: 316 Stainless Steel
- Materials in Contact with the Sample Gas: 316Ti Stainless Steel
- Materials in Contact with the Sample Gas: FPM
- Materials in Contact with the Sample Gas: Graphite
- Materials in Contact with the Sample Gas: Quartz Glass
Mounting
- Rack-Mounted
Operating Pressure
- psia: 13.05 to 29.01 (kPa: 90 to 200, bar: 0.9 to 2)
Overpressure & Static Pressure Limits
- Fault Caused by Process Under or Overpressure: No Fault as Long as the Differential Pressure ∆P at the Dilution Unit is > psig: 7.252 (kPa: 50, bar: 0.5) & Test Gas is Given to the Probe Under Process Conditions
Power Supply
- Power Supply: 230 V 50 Hz, 800 W
Pressure Range
- Dilution Gas Pressure on Inlet of Pressure Controller - psig: 65.27 to 232.1 (kPa: 450 to 1,600, bar: 4.5 to 16)
Ratio
- Dilution - 10:1 to 500:1
Temperature Range
- Electrically Heated: 0° to 320° C (32° to 608° F)
- Temperature Controller: Capillary Thermostat Adjustable 0° to 180° C (32° to 356° F)