Non-rotating torque meters with hexagonal head.
Features
  • Broad range of capacities: from 2 to 1,000 Nm
  • Easy to install
  • Compact design
  • Protection IP 54
  • Materials:
    • Stainless steel (6500)
    • Nickel plated steel (6505)

  • Available options (non exhaustive list):
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)
    • Double strain-gauge bridge
    • Cable output with connector

The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
show more
Non-rotating torque meters with hexagonal head.
Features
  • Broad range of capacities: from 2 to 1,000 Nm
  • Easy to install
  • Compact design
  • Protection IP 54
  • Materials:
    • Stainless steel (6500)
    • Nickel plated steel (6505)

  • Available options (non exhaustive list):
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)
    • Double strain-gauge bridge
    • Cable output with connector

The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
Part Number / SKU

6500/6505

Loading...
Selected Configuration

    6500/6505

      Specifications

      Agency Approvals

      • ATEX Intrinsic Safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
      • CE

      Environmental Protection

      • IP54

      Operating Temperature

      • 180° C (356° F) - High Service Temperature

      Temperature Range

      • -10° to 45° C (14° to 113° F) - Nominal

      Storage Temperature

      • -50 to 85° C (-58° to 185° F)

      Service Temperature

      • -30 to 70° C (-22° to 158° F)

      Temperature Coefficient

      • <±0.035% of Full Scale/10° C (18° F) - Zero Signal
      • <±0.05% of Full Scale/10° C (18° F) - Temperature Coefficient of the Sensitivity

      Repeatability

      • <±0.1% of Full Scale - Error

      Sensitivity

      • <±0.3% - Tolerance
      • 1.5 mV/V

      Linearity

      • <±0.25% of Full Scale - Error

      Static Lateral Force

      • 10% of Full Scale

      Zero Balance

      • ±0.02 mV/V

      Resistance

      • 352 ±2 Ohms - Input/Output

      Cable Length

      • 1.6 to 20 feet (0.5 to 6.0 meters)

      Communication

      • RS-232C
      • RS-485
      • USB

      Insulation Resistance

      • >5,000 MegaOhms (50 V)

      Load Limit

      • 120% of Full Scale

      Load

      • >300% of Full Scale - Breaking
      • 40% of Full Scale - Dynamic Loading

      Excitation Voltage

      • 10 Vdc
      • 3-12 Vdc - Nominal Range

      Capacity

      • 2 to 1,000 Nm

      Enclosure/Body Material

      • Nickel-Plated Steel (6505)
      • Stainless Steel (6500)

      Applications

      • Calibration Standards
      • Torque Control