The option converts the signal from the Wheatstone bridge (mV/V) in a robust industrial standardized 4 to 20 mA signal.
Features
  • Internal or external mounting depending of the size of the transducer
  • If external: cylindrical housing in nickel plated brass or rectangular box in Aluminum (low-cost version)
  • Protection:
    • Cylindrical housing: IP 67
    • Rectangular box: IP 65

  • Available version with shifted zero for bidirectional utilization for versions 4 to 20 mA and 0-10 V
  • Version 2-Wires: protection against wrong cabling
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
show more
The option converts the signal from the Wheatstone bridge (mV/V) in a robust industrial standardized 4 to 20 mA signal.
Features
  • Internal or external mounting depending of the size of the transducer
  • If external: cylindrical housing in nickel plated brass or rectangular box in Aluminum (low-cost version)
  • Protection:
    • Cylindrical housing: IP 67
    • Rectangular box: IP 65

  • Available version with shifted zero for bidirectional utilization for versions 4 to 20 mA and 0-10 V
  • Version 2-Wires: protection against wrong cabling
The above description encapsulates the entire product series. Specifications for individual configurations may vary depending on the selection chosen.
Part Number / SKU

OPTION-AO J/C/C6/T

Loading...
Selected Configuration

    OPTION-AO J/C/C6/T

      Specifications

      Agency Approvals

      • ATEX
      • CE
      • CSA
      • IECEx

      Environmental Protection

      • IP65 - Rectangular Box
      • IP67 - Cylindrical Housing

      Temperature Range

      • -10° to 45° C (14° to 113° F) - Nominal

      Service Temperature

      • -40° to 85° C (-40° to 185° F)

      Temperature Coefficient

      • <±0.025% of Full Scale/10° C (18° F)
      • <±0.05% of Full Scale/10° C (18° F)
      • <±0.064% of Full Scale/ 10° C (18° F)
      • <±0.14% of Full Scale/ 10° C (18° F)
      • <±0.065% of Full Scale/ 10° C (18° F)

      Consumption

      • ≤23 mA
      • ≤25 mA
      • Maximum 45 mA

      Measuring Error

      • <±0.02% of Full Scale - Combined Error

      Housing Style

      • Cylindrical Housing
      • Rectangular Box

      Supply Voltage

      • 9 to 30 Vdc

      Input

      • 0.5-5.5 mV/V

      Resistance

      • ≤750 to >10,000 Ohms

      Load Impedance

      • 350 to 5,000 Ohms - Impedance of Wheatstone Bridge

      Bandwidth

      • 0 to 1,000 Hz

      Sensor Excitation

      • 0.5 to 8 Vdc

      Output

      • -10 to 10 V (11 Maximum)
      • 4-20 mA (24 Maximum)

      Mounting

      • Universal Internal or External

      Enclosure/Body Material

      • Aluminum
      • Nickel-Plated Brass

      Applications

      • Industrial Applications
      • Load and Compression Sensing
      • Overhead Travelling Cranes
      • Torque Measurement